Application of TS-780H Heat Flow Meter in RF Test
2022-12-06 11:26:33

High and low temperature test of RF shielding in integrated circuits. The advanced TS-780H high and low temperature heat flow meter system can now be paired with various chambers in the RF industry, and IC tests at various temperatures can be easily carried out in a controlled RF environment. RF testing at extreme temperatures is a challenge not only to the semiconductor industry, but also to the entire electronics industry. ThermoTST TS-780 is a precision high and low temperature impact heat flow meter with a wider temperature range of - 80 ℃ to+225 ℃ (the temperature in the box shall be calculated according to the volume/load). The DUT function can ensure the temperature of the box and provide temperature stability of<± 1 ° c; Advanced temperature conversion capability. The temperature conversion from - 55 ℃ to+125 ℃ is less than 90 seconds (different volumes, different conversion capabilities). The heat flow meter supports automatic programming. When the flex hose is paired with the d box chamber, the head can be designed to directly contact the test sample in an RF isolation environment because of its flexible connectivity.

 

Specifications

Type

TS-780H

Temperature Range

-80 ºC to + 225 ºC

Typical Temperature Transition Rate

-55 ºC to + 125 ºC about10s

Temperature Accuracy

± 1 ºC

Temperature Set, Display and Resolution

± 0.1 ºC

System Airflow Output

4 ~24 SCFM(1.9 L/s ~ 11.3L/s)

Operation Interface

Color touch screen,10" TFT

language

Chinese/English

Operation mode

Manual or Program