TS-760 Temperature Forcing Systems Microprocessor chip high and low Temperature testing applications
2022-11-24 10:56:35

ThermoStream TS-760 is used to test MCU/SoC microprocessor chips
In electronics, aerospace, communication experiments and other industries, there are strict requirements for the chip used. Whether the chip can work properly in a harsh environment and how reliable it is has become an important concern. However, due to temperature changes, the traditional verification method has a slow stability speed and cannot provide a rapidly changing temperature environment. It is difficult to meet the corresponding testing needs. Chinacryo Temperature Forcing Systems solves the defects of traditional verification methods and provides rapid high and low temperature impact capability.

TS-760 is used in MCU/SoC microprocessor chip test solutions
In conducting microprocessor chip testing, customers require test temperatures of -40 to 125 °C, ts-760 tests in the temperature range of -65 to +225°C, output gas flow of 4 to 18 SCFM, and temperature accuracy of ±1 °C. This product perfectly addresses customer requirements. High and low temperature test machine TS-760 with Delta Design test machine for microprocessor chip testing, effectively improve the speed and accuracy of chip testing, rapid electrical performance testing, failure analysis, reliability evaluation in electrical work.

Microprocessor chip high and low temperature test method
1. Place the microprocessor chip to be tested in a glass cover
2. The operator sets the temperature range to be tested
3. Start ThermoStream TS-760, use air compressor to pass dry and clean air into refrigerator for low temperature treatment, then air reaches heating head through external pipeline for heating, and air enters test chamber through heat flow hood. The temperature sensor in the glass cover can monitor the current internal temperature of the chamber in real time. Temperature Forcing Systems TS-760 has its own overheating temperature protection system, and the operator can also set the high and low temperature limit point according to actual needs.